Female thread anchor with collar and metric thread for economical anchoring in concrete, zinc plated steel
  • Small drill hole depth

  • High load-bearing capacities

  • Visual setting check and hand protection when installing with the marking/spreading tool

  • Mechanical setting tool makes installation quicker and easier

  • Immediate load-bearing capacity — no waiting

  • Attached part can easily be removed at any time

  • W-ED/S has collar enabling anchor to be installed flush with the surface and preventing it slipping further into the drill hole (safer installation)

  • The attached part can be anchored with a fastening screw or a threaded rod

  • No installation torque required
Proof of Performance
  • ETA-02/0044 for individual fixing point, option 7, uncracked concrete

  • ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120)
Notice

Drive-in anchor W-ED/A4 see [13.2]

Application area
Suspended ceilings

Drill hole

Clean the drill hole

Knock in anchor until flush

Anchor with expander tool

Fit component, apply torque

  • ETA-02/0044 for individual fixing point, option 7, uncracked concrete

  • ETA-05/0120 for anchors in a redundant non-structural system, uncracked and cracked concrete

  • Fire resistance: F30, F60, F90 and F120; exposure to fire according to DIN 4102-2:1977-09 (UTTC - uniform temperature time curve)

  • Fire resistance: R30, R60, R90 and R120; TR020 (included in ETA-05/0120)
Product information

Datasheets(X)

CAD data (available after login)

Certificates/ Documents

 | 

 | 

Application area
  • Individual fixing point: Normal weight concrete C20/25 to C50/60 (uncracked concrete)

  • Anchors in a redundant non-structural system: Anchorage of non-load-bearing systems (cracked and uncracked concrete)

  • Suitable for fastening threaded rods, metal structures, metal profiles, lattices, cable conduits, pipes, mounting rails etc.

  • For use in concrete < C20/25 and pressure-resistant natural stone (without approval)

  • W-ED/S, W-ED/S-BND and W-ED M5 may only be used in dry indoor conditions

Anchor diameter

10 mm

Anchor length (L H)

40 mm

Min./max. required screw-in depth

11-15 mm

Material

Steel

Surface

Zinc plated

Nominal drill-bit diameter (d 0)

12 mm

Drill hole depth (h 0)

40 mm

Effective anchoring depth (h ef)

40 mm

Torque during anchoring (T inst)

15 Nm

Through-hole in the component to be connected (d f)

12 mm

Installation parameters in hollow-core prestressed concrete ceilings
Anchor size [mm] M6x25M8x25M10x25M12x25
Mirror thicknessdb ≥ [mm]35 (30)2)
Minimum axis distancesmin [mm]200
Minimum edge distancecmin [mm]150
Nominal drill ∅d0 [mm]8101215
Drill cutting ∅dcut ≤ [mm]8,4510,4512,515,5
Drill hole depthh0 = [mm]25252525
Through hole in the component being connecteddf ≤ [mm]791214
Thread depth (max. length of thread engagement)Lth [mm]12121212
Minimum length of thread engagementLsdmin ≤ [mm]681012
Torque while installing anchorTinst ≤ [Nm]481535
Spacing between cavity axeslc ≥ [mm]100
Spacing between tensioning strandslp ≥ [mm]100
Spacing between tensioning strands and drill holeap ≥ [mm]50
Performance data in uncracked concrete - individual fixing point (screw 4.6-8.8)

Anchor size [mm]M5x251)6)M6x306)M8x306)M8x40M10x306)M10x40M12x50M16x65M20x80
Admissible centric tension load3)
on an individual anchor without the influence of the edge distance
Compressive zone
(uncracked concrete C20/254), s ≥ 3 hef, c ≥ cmin)
Nadm [kN] = C20/244)Frec
1.4
3,33,33,63,35,17,110,514,3
Admissible shear load3)
on an individual anchor without the influence of the edge distance
Compressive zone
(uncracked concrete C20/254), s ≥ 3 hef, c ≥ cmin)
Vadm [kN] = C20/244)5)Frec
1.5
2,13,93,94,04,19,016,826,2
Admissible bending moment7)Madm [Nm]-3,38,115,827,871,0138,6
Fire resistance8) according to UTTC (uniform temperature time curve)F30 [kN]-1,71,73,0-4,76,912,518,0
F60 [kN]-0,70,71,5-2,43,55,68,5
F90 [kN]-0,40,40,8-1,31,83,55,5
F120 [kN]-0,30,30,6-1,01,42,54,4
Performance data in cracked and uncracked concrete - anchors in a redundant non-structural system (screw 4.6-8.8)
Anchor size [mm]M6x25M6x30M8x25M8x30M8x40M10x25M10x30M10x40M12x25M12x50M16x65
Anchors in a redundant non-structural system in concrete10)Fadm [kN] = C12/15 - C16/204)1,2-1,2--1.79)--1.79)--
Fadm [kN] = C20/25 - C50/604)1.79)1,21.99)1.79)2.09)2.19)2.09)2.09)2.19)2.49)6.39)
Admissible bending moment7)Madm [Nm]3,38,115,827,871,0
Admissible load when exposed to fire10)R30 [kN]0,40,80,60,91,50,60,91,50,61,54
R60 [kN]0,40,80,60,91,50,60,91,50,61,54
R90 [kN]0,30,40,60,90,90,60,91,50,61,53,7
R120 [kN]0,30,30,50,50,50,50,71,00,51,22,4
Performance data in hollow-core prestressed concrete ceilings – anchors in a redundant non-structural system (screw 4.6-8.8)
Anchor size [mm]M6x25M8x25M10x25M12x25
Mirror thicknessdb ≥ [mm]35 (30)2)
Anchors in a redundant non-structural system in hollow-core prestressed concrete ceilingsFadm [kN]1.79)1.99)2.19)2.19)
Admissible bending moment7)Madm [Nm]3,38,115,827,8

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information